Enclosure: 18-way flush mount design featuring a durable white plastic front cover assembly with a transparent, smoked, hinged inspection door, and a robust galvanised steel tray/back box for in-wall installation.
Mains Protection: Includes 1 x CHINT NXBLE-63Y 63A 30mA Type C RCBO (Residual Current Breaker with Overcurrent protection), 4-module width, with 6kA breaking capacity.
Circuit Protection (MCBs):
1 x CHINT eBC 32A Type C Miniature Circuit Breaker (MCB) with 3kA breaking capacity.
4 x CHINT eBC 20A Type C Miniature Circuit Breakers (MCB) with 3kA breaking capacity.
2 x CHINT eBC 10A Type C Miniature Circuit Breakers (MCB) with 3kA breaking capacity.
Spare Ways: A generous 7 spare ways available for extensive future circuit additions and upgrades.
DIN Rail: Pre-fitted standard 35mm DIN rail securely mounted within the galvanised steel tray.
Standards Compliant: All components comply with relevant IEC standards (IEC61009-1 for RCBO, IEC/EN 60898-1 for MCBs).
Certification: Components are CE marked.
Easy Access: Numbered positions for clear circuit identification within the enclosure.
Discreet, Professional Installation: Flush mounting ensures the distribution board integrates seamlessly into the wall for a clean, unobtrusive aesthetic.
Simplified Installation Process: Pre-populated with essential breakers, significantly reducing on-site assembly and installation time.
Superior Durability and Protection: The galvanised steel tray provides enhanced mechanical strength, rigidity, and protection for the internal components.
Maximum Electrical Safety: The 4-module RCBO main switch offers critical protection against earth faults, overloads, and short circuits, safeguarding people and property.
Flexible and Comprehensive Circuit Management: A versatile mix of MCB ratings (10A, 20A, 32A) caters to a wide range of electrical load requirements.
Highly Scalable for Future Growth: With 7 spare ways, this board provides ample capacity for significant future electrical expansions or system modifications.
Convenient Status Monitoring: The transparent inspection door allows for quick visual checks of breaker statuses without opening the main cover.
Trusted Quality and Reliability: CHINT components are recognized for their adherence to international safety standards and dependable long-term performance.
Type: Flush Mount Consumer Unit / Distribution Board
Ways: 18 Total Ways (11 Populated, 7 Spare)
Material:
Front Cover Assembly: High-impact thermoplastic (Body: White, Inspection Door: Smoked Transparent)
Back Box/Tray: Galvanised Steel
Mounting: Pre-installed 35mm DIN Rail in steel tray
Dimensions (Approximate, for flush mounting): (Specific cut-out and overall dimensions for the steel tray and front cover should be verified from manufacturer data)
Mains Isolator: CHINT NXBLE-63Y RCBO
Model: NXBLE-63Y
Type: Residual Current Operated Circuit Breaker with Overcurrent Protection (RCBO)
Module Width: 4 Ways (e.g., 2P configuration occupying approx. 72mm)
Rated Current (In): 63A
Rated Residual Operating Current (IΔn): 30mA (0.03A)
Tripping Curve: Type C
Rated Voltage (Ue): 230V AC (typical for 1P+N or 2P single phase)
Frequency: 50/60Hz
Rated Short-circuit Breaking Capacity (Icu/Ics): 6000A (6kA)
Rated Impulse Withstand Voltage (Uimp): 4kV
Standard: IEC61009-1
Mechanical Life: 20,000 cycles
Electrical Life: 10,000 cycles
Certification: CE
Model: eBC
Type: Miniature Circuit Breaker (MCB)
Poles: 1P
Included Ratings & Quantities:
1 x 32A
4 x 20A
2 x 10A
Tripping Curve: Type C (5-10In)
Rated Voltage (Ue): 230/400V AC
Rated Short-circuit Breaking Capacity (Icn): 3kA (as per eBC specification for 1-63A)
Rated Impulse Withstand Voltage (Uimp): 4kV
Standard: IEC/EN 60898-1
Electrical Life: 4,000 cycles
Mechanical Life: 10,000 cycles
Protection Degree (Breaker itself): IP20
Terminal Connection Type: Cable/Pin-type busbar
Terminal Size (Cable): 1-25 mm²
Mounting: On DIN rail EN 60715 (35mm)
Certifications: CE, SAA, etc. (as per datasheet)
Large Residential Properties and Custom Homes: Perfect for managing extensive electrical systems with numerous circuits and potential for future additions.
Commercial Establishments: Suitable for offices, retail spaces, restaurants, and clinics requiring a high-capacity, flush-mounted, and aesthetically pleasing solution.
Light Industrial Applications: Can effectively serve workshops or small manufacturing units where a neat and robust installation is preferred.
New Constructions and Major Renovations: Ideal for projects demanding significant circuit capacity, robust protection, and a clean, integrated finish.
Installations requiring superior mechanical protection for the back box and a high degree of future-proofing.
Expert Installation Essential: Installation must be carried out by a qualified and certified electrician in strict accordance with all local electrical codes, safety regulations, and flush-mounting best practices.
Accurate Wall Recess Preparation: Ensure the wall opening (cut-out) for the galvanised steel tray is precisely dimensioned to guarantee a secure and proper fit, facilitating correct alignment of the front cover.
Consistent RCBO Functional Checks: Regularly test the RCBO's operation using the "T" or "Test" button (monthly testing is highly recommended) to ensure its ongoing protective capability.
Strategic Load Planning for Expansion: When utilizing the ample spare ways, consult with your electrician for optimal load balancing and to ensure that the total connected load remains within the main switch's capacity.
Adherence to Cable Sizing Standards: Always use appropriately sized cables for each circuit, considering its current rating, run length, and specific installation conditions.
Verify All Connections: Confirm that all electrical terminal connections are securely tightened to the manufacturer's specified torque values to ensure optimal safety, performance, and reliability.
Systematic Circuit Labeling: Clearly and accurately label each circuit breaker for straightforward identification, efficient fault-finding, and simplified future maintenance or modifications.