The Schneider 2P 6kA Acti9 iC60A MCB C-Curve DIN is a precision-engineered miniature circuit breaker designed for high-performance protection in various single-phase and two-phase AC electrical systems.
Characteristic | Value | Details / Standard |
---|---|---|
Range | Acti9 | Part of Schneider Electric's premium modular protection range |
Device Application | Distribution | Designed for general electrical power distribution systems |
Product or Component Type | Miniature Circuit-Breaker (MCB) | Specifically, an Acti9 iC60a series MCB |
Device Short Name | iC60a | |
Poles Description | 2P | Two protected poles |
Number of Protected Poles | 2 | Both poles provide overcurrent protection |
Rated Current ([In]) | 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A | Available in various ampere ratings to suit diverse load requirements |
Network Type | AC | Designed exclusively for Alternating Current circuits |
Trip Unit Technology | Thermal-magnetic | Combines thermal (overload) and magnetic (short-circuit) protection |
Curve Code | C | Tripping characteristic for circuits with moderate inrush currents |
Breaking Capacity ([Icu]) | 4500 A Icn at 400 V AC 50/60 Hz | Conforming to EN/IEC 60898-1 |
10 kA Icu at 220...240 V AC 50/60 Hz | Conforming to EN/IEC 60947-2 | |
6 kA Icu at 380...415 V AC 50/60 Hz | Conforming to EN/IEC 60947-2 | |
Utilisation Category | Category A | Conforming to EN 60947-2 and IEC 60947-2 (General purpose) |
Suitability for Isolation | Yes | Conforming to EN 60898-1, EN 60947-2, IEC 60898-1, IEC 60947-2 |
Network Frequency | 50/60 Hz | Compatible with standard global power grid frequencies |
Magnetic Tripping Limit | 8 x In +/- 20% | Defines the range (8.5 to 11.5 times In) at which the magnetic trip operates |
Rated Service Breaking Capacity ([Ics]) | 10 kA 100% Icu at 220...240 V AC 50/60 Hz | Conforming to EN/IEC 60947-2 and IEC 60947-2 |
6 kA 100% Icu at 380...415 V AC 50/60 Hz | Conforming to EN/IEC 60947-2 and IEC 60947-2 | |
4500 A 100% Icn at 400 V AC 50/60 Hz | Conforming to EN 60898-1 and IEC 60898-1 | |
Limitation Class | 3 | Conforming to EN 60898-1 and IEC 60898-1 (High current limiting capability) |
Rated Insulation Voltage ([Ui]) | 500 V AC 50/60 Hz | Conforming to EN 60947-2 and IEC 60947-2 (Max continuous voltage insulation can withstand) |
Rated Impulse Withstand Voltage ([Uimp]) | 6 kV | Conforming to EN 60947-2 and IEC 60947-2 (Max transient overvoltage device can withstand) |
Contact Position Indicator | Yes | Visual indicator for clear ON/OFF status |
Control Type | Toggle | Manual ON/OFF operation |
Local Signalling | Trip indicator | Visual indication that the breaker has tripped due to a fault |
Mounting Mode | Removable comb busbar installed, Clip-on | Facilitates easy installation and maintenance with comb busbars |
Mounting Support | DIN rail | Standardized 35mm symmetrical DIN rail |
9 mm Pitches | 4 | Standard modular width unit for panel design (4 pitches = 36mm width) |
Height | 81 mm | |
Width | 36 mm | |
Depth | 78.5 mm | Consistent depth across the 2P Acti9 iC60a range |
Colour | White | Aesthetic color for integration into electrical panels |
Net Weight | 0.210 kg - 0.246 kg (approx.) | Varies slightly by current rating (e.g., 224g for 1A, 246g for 63A) |
Mechanical Durability | 10,000 cycles | Number of no-load (ON/OFF) operations the breaker can withstand |
Electrical Durability | 4,000 cycles | Number of operations under electrical load the breaker can withstand |
Connections - Terminals | Single terminal (top or bottom): 1...25 mm² rigid | Accommodates a range of rigid conductor sizes |
Single terminal (top or bottom): 1...16 mm² flexible | Accommodates a range of flexible conductor sizes | |
Wire Stripping Length | 14 mm for top or bottom connection | Recommended length of insulation to strip for proper connection |
Tightening Torque | 2 N.m top or bottom | Recommended torque for securing terminal connections |
Earth-Leakage Protection | Separate block | This is an MCB; earth-leakage protection requires a separate device (e.g., Acti9 iID RCCB) |
IP Degree of Protection | IP20 B conforming to EN/IEC 60529 | Protected against solid objects >12.5mm and access to hazardous parts; no water protection |
Pollution Degree | 3 conforming to EN 60947-2 & IEC 60947-2 | Suitable for industrial environments where conductive pollution may occur |
Overvoltage Category | II | Suitable for appliances and portable equipment with temporary overvoltages |
Tropicalisation | 2 conforming to EN/IEC 60068-2-78 | Suitable for humid and warm climates |
Relative Humidity | 95 % (non-condensing) | Maximum relative humidity allowed without condensation |
Operating Altitude | 0...2000 m | Maximum altitude for specified performance |
Ambient Air Temperature for Operation | -35...70 °C | Optimal temperature range for continuous operation |
Ambient Air Temperature for Storage | -40...85 °C | Safe temperature range for storage and transportation |
Standards | EN 60947-2, EN 60898-1, IEC 60898-1, IEC 60947-2 | Complies with multiple international and European product standards |
Product Certifications | CE | European Conformity marking |
Contractual Warranty | 18 months | Manufacturer's warranty period |
Environmental Footprint | 23-45 kg.eq.CO2 (Total Life Cycle) | Varies slightly by current rating; lower for lower In, higher for higher In |
Recycled Metal Content | 0% at CR level | Indicates the percentage of recycled metal content at the component level |
Packaging Material | Made with recycled cardboard; without single-use plastic | Sustainable packaging practices (as per provided datasheets) |
EU RoHS Directive | Compliant | Adheres to the Restriction of Hazardous Substances Directive |
SCIP Number | 26ff71d1-98cf-4280-8725-455b9a6b2fb9 (example) | Substance of Concern In Products database identification number |
REACH Regulation | REACH Declaration available | Complies with Registration, Evaluation, Authorisation and Restriction of Chemicals regulation |
WEEE Compliance | Product must be disposed of on European Union markets following specific waste collection and never end up in rubbish bins | Adheres to the Waste Electrical and Electronic Equipment Directive for responsible disposal |
The Schneider 2P 6kA Acti9 iC60A MCB C-Curve DIN is perfectly suited for a comprehensive range of electrical distribution applications requiring premium performance and reliability in single-phase and specific two-phase systems.